Personal tools
You are here: Home Virgo Data Analysis Noise study WSR5 veto study Pr_SSFS_Visu
Document Actions

Pr_SSFS_Visu

Up one level
Veto study of the total channel Pr_SSFS_Visu.
Histogram of the SNR of the Pr_SSFS_Visu channel (WDF) by Marina Del Prete — last modified 2007-06-05 18:23
Histogram of the SNR of the Pr_SSFS_Visu channel analised with the WDF program.
Events above thresholds and used in the veto analysis versus the SNR thresholds. by Marina Del Prete — last modified 2007-06-05 18:23
Plot of the events of the Pr_SSFS_Visu channel above thresholds and vetoed versus SNR threshold. The study is done for the veto windows values from 0 to 0.5 seconds in steps of 0.05 seconds. The SNR thresholds are varied from 15 to 105 in of 10. The number of eventa can be too low for SNR threshold above 65-75.
Use Percentage vesus SNR thresholds by Marina Del Prete — last modified 2007-06-05 18:23
Plot of Use Pecentage versus the SNR thesholds. The study is done for the veto windows values from 0 to 0.5 seconds in steps of 0.05 seconds. The SNR thresholds are varied from 15 to 105 in of 10. The use percentage increases for values of SNR threshold above 65.
Use percentage versus Veto Windows (Dt) by Marina Del Prete — last modified 2007-06-05 18:23
Plot of Use Pecentage versus Dt. The study is done for the veto windows values from 0 to 0.5 seconds in steps of 0.05 seconds. The SNR thresholds are varied from 15 to 105 in of 10. The Knee is about at Dt=0.1, 0.15 s. For Dt=0.1s and SNR=55 the use percentage is about 27%.
Veto Efficiency versus Veto Windows (Dt) by Marina Del Prete — last modified 2007-06-05 18:23
Plot of Veto Efficiency versus Dt. The study is done for the veto windows values from 0 to 0.5 seconds in steps of 0.05 seconds. The SNR thresholds are varied from 15 to 105 in of 10 For Dt=0.1s and SNR=55 the veto efficiency is about 0.07%.
Dead Time versus Veto windows (Dt) by Marina Del Prete — last modified 2007-06-05 18:23
Plot of Dead Time versus Dt. The study is done for the veto windows values from 0 to 0.5 seconds in steps of 0.05 seconds. The SNR thresholds are varied from 15 to 105 in of 10.ForDt=0.1s and SNR=55 the dead time is about 0.02%.
Veto Efficiency versus SNR thresholds by Marina Del Prete — last modified 2007-06-05 18:23
 
Dead Time versus SNR thresholds by Marina Del Prete — last modified 2007-06-05 18:23